Over 5 million soldOver 5 Million Locks Sold
GoKeyless TrustedTrusted Since 2003
Categories
  • Industry
  • Wire Gauge Selection Guide

    by Steve LaTart 1 min read

    WIRE GAUGE SELECTION GUIDE

    Load Current @ 24V
    Total One-Way
    Length of Wire
    Run (ft.)
    1/4A 1/2A 3/4A 1A 1-1/4A 1-1/2A 2A 3A
    100 24 20 18 18 16 16 14 12
    150 22 18 16 16 14 14 12 10
    200 20 18 16 14 14 12 12 10
    250 18 16 14 14 12 12 12 10
    300 18 16 14 12 12 12 10 –
    400 18 14 12 12 10 10 – –
    500 16 14 12 10 10 – – –
    750 14 12 10 10 – – – –
    1000 14 10 10 – – – – –
    1500 12 10 – – – – – –
    Load Current @ 12V
    Total One-Way
    Length of Wire
    Run (ft.)
    1/4A 1/2A 3/4A 1A 1-1/4A 1-1/2A 2A 3A
    100 20 18 16 14 14 12 12 10
    150 18 16 14 12 12 12 10 –
    200 16 14 12 12 10 10 – –
    250 16 14 12 10 10 10 – –
    300 16 12 12 10 10 – – –
    400 14 12 10 – – – – –
    500 14 10 10 – – – – –
    750 12 10 – – – – – –
    1000 10 – – – – – – –
    1500 10 – – – – – – –

    Wire Gauge Chart courtesy of Electronic Locking Devices by John L. Schum